NorthStar Loop Detector - NP2-120 Single Channel - Dual Relay Vehicle Detector
$ 53.82
- Description
- Size Guide
Description
NorthStar Loop Detector - NP2-120 Single Channel - Dual Relay Vehicle DetectorNorthStar Loop Detector - NP2-120 Single Channel - Dual Relay Vehicle Detector
- 10 selectable Sensitivities.
- 4 selectable Frequencies.
- Wrong voltage protection.
- Output Timing – Extend & Delay.
- Selectable Presence times.
- Selectable Pulse lengths.
- Separate Power, Detect and Fault Indicators.
- Automatic Sensitivity Boost.
The
NorthStar Loop Detector - NP2-120 Single Channel
has been specifically designed and engineered for use in the Parking/Access Control industries. With standard operations including programmable pulse and presence options, fail-safe or fail-secure operation, compatibility with all radio controls, timing features and more, the NP2 covers your detection needs.
The
NorthStar Loop Detector - NP2-120 Single Channel
wide inductance range allows for use with small loops sometimes found in the Parking/Access Control industries (for recommended loop sizes please consult the Northstar Loop Information Guide).
Separate indicators for power on, detect relay 1, detect relay 2 and fault provide for quick visual verification of proper operation. Loop diagnostics are easily viewed with the front panel fault indicator, differentiating between current and historical faults thus facilitating troubleshooting.
Small size and full list of features lend the
NorthStar Loop Detector - NP2-120 Single Channel
to any Parking/Access Control use from simple presence detection to configured pulse/presence lengths with output extensions and/or delays.
Reliable operation and long field life are key engineering goals in every Northstar product.
NP2 Specifications
Rear Panel DIP Switch Selections
Relay 1
Extend – switch 1 is for extending the detector output after the vehicle has left the loop. Switch 1 in the OFF position provides no extension. Switch 1 in the ON position provides a 5 second extension once the vehicle leaves the loop. This extension applies to relay 1 only.
Delay – switch 2 is for providing a 2 second delay, detector will ignore the vehicle until the vehicle has been present over the loop for 2 seconds. Switch 2 in the OFF position provides no delay. Switch 2 in the ON position provides for the 2-second delay. This delay applies to relay 1 only.
Presence Time – switch 3 provides for either a 1 hour presence or permanent presence. Switch 3 in the OFF position provides for 1 hour of presence. Switch 3 in the ON position provides for permanent presence. The above presence settings apply to relay 1 only. (Other options are available).
Relay 2
Pulse Length – switch 4 provides for either a 250mS pulse length or a 500mS pulse length. Switch 4 in the OFF position provides a 250mS (standard) pulse length.
Switch 4 in the ON position provides a 500mS pulse length.
Operating Mode – switch 5 and switch 6 determine the operating mode for Relay 2. The four modes are as follows:
Switch 5 and switch 6 OFF provides pulse-on-entry.
Switch 5 ON & switch 6 OFF provides pulse-on-leaving.
Switch 5 OFF & switch 6 ON provides for presence.
Switch 5 and switch 6 ON provides a fault output.
Front Panel Selections
Sensitivity – controlled by front panel rotary switch.
- 0 = Low sensitivity
- 9 = High sensitivity
Medium sensitivity is used for most applications; this is a setting of 4 or 5. Always use the lowest sensitivity setting that detects the desired vehicles.
Frequency – four separate settings controlled by front panel.
DIP switches.
- 2+1 = High.
- 2+0 = Medium High.
- 1+0 = Medium Low.
- 0+0 = Low.
Reset – front panel reset performs a hard reset of the
detector.
Ordering Information:
Unit Voltage Part #
120 VAC NP2-120
Factory Settings
- Set to HI frequency.
- Set to Medium sensitivity (5).
- Extend/Delay in the OFF position.
- Presence time set to 1 hour.
- Pulse length set to 250msec.
- Relay 1 = fail-safe.
- Relay 2 = fail-secure.
Relay Output Rating: 7A 277VAC/30VDC.
Power: 120 VAC
(70mA DC or 1W AC)
Inductance Range: 20uH to 1500uH.
Temperature Range: -30 F to +180 F.
Lead-In Length: up to 2500 ft. with proper lead-in and loop.
Mechanical: 1 3/8”w X 3 3/32”h X 3 ½”l.
Weight: 8 oz.
Supply Voltage – incorrect voltage supplied to the unit will
not result in damage, the unit will simply not operate until
correct voltage is supplied. No fuses need to be reset.
Indicators – front panel indicators include:
- Power – Green, solid with correct power supplied.
- Relay 1 – Red, solid during detect.
- Relay 2 – Red, solid during detect.
- Fault – Yellow, solid during current fault, flashing for historical fault.
Sensitivity Boost – automatic during detect except in the highest sensitivity setting (9).
Factory Options:
- Presence lengths of 15, 30, 60 minutes or permanent.
- Pulse lengths of 250mS, 500mS, 1, 2 or 4 seconds.
- Extend times of 0, 2, 5 or 10 seconds.
- Delay times of 0, 1, 2 or 4 seconds.
- Relay 1 fail-safe or fail-secure.
- Relay 2 fail-safe or fail-secure.
Note: Bold indicates standard configuration from the factory.
Connector – 11P Amphenol
Pin # Function Color
1 Power (+) Black
2 Power (-) White
3 Relay 2 N.O. Orange
4 Ground Green
5 Relay 1 Com Yellow
6 Relay 1 N.O. Blue
7 Loop Gray
8 Loop Brown
9 Relay 2 Com Red
10 Relay 1 N.C. White/Blk
11 Relay 2 N.C. White/Red
Note: The above connection is shown with correct power supplied
and no vehicle present.